The most important factor in the development of bonds from ions on the surface. The surface encourages the growth of the bond. These bonds are also formed in normal water pipes. According to the “Brownian motion of molecules” a bond is created whenever a certain number of calcium and magnesium ions meet in a certain constellation. This creation of bonds is completely random. With the knowledge about these surfaces, we set out to develop a surface that the calcium ions would accept as a template and form into crystals. Critical for the development of crystals is the enthalpy.

27 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

Evolet Anti-Scale Media

nIntroduction Carbonate hardness:nOur drinking water comes from the groundwater. This groundwater is constantly being added onto by rainwater. When the rain passes through the atmosphere, it enriches itself with carbon dioxide (CO2). Carbonic acid (H2CO3) is formed from the connection of H2O (water) and CO2 (carbon dioxide). Carbonic acid is the solvent of calcium. After the rain sinks into the soil, the carbonic acid extracts the calcium from calcium-rich stone. Through this process hydrogen carbonate [Ca(HCO3)2] is formed. This extraction process ends when the water is saturated with calcium. This means that the carbonic acid and the Calcium are in a carbonic acid – calcium equilibrium. Depending on the ground quality (amount of calcium and amount of carbonic acid) more or less calcium is extracted into the water.nnA real-life example of an artificial templatenIf you have a saturated salt solution in a glass, no crystals will form. However, if you put a wool thread into the water, crystalsnwill start to form on it. The wool thread functions as an artifi cial template, reducing the enthalpy and encouraging the dissolved salt to form a crystal.nnDescaling effect of the Evolet Anti-Scale medianThe Evolet Anti-Scale media also has a descaling effect on scale already present in old pipes, hardware, etc. The water coming from the media is saturated with free CO2 .Carbonate hardness in already existing scale are removed by this CO2 saturated water and slowly floating in the water. This way existing scale is usually heavily reduced or removed within 1 to 2 months.nnnLearn MorennEvolet Anti-Scale MediannHow does NSF Certified Evolet Anti-Scale Media work?nThe most important factor in the development of bonds from ions on the surface. The surface encourages the growth of the bond. These bonds are also formed in normal water pipes. According to the “Brownian motion of molecules” a bond is created whenever a certain number of calcium and magnesium ions meet in a certain constellation. This creation of bonds is completely random. With the knowledge about these surfaces, we set out to develop a surface that the calcium ions would accept as a template and form into crystals. Critical for the development of crystals is the enthalpy. This is the energy required to form a crystal or a new layer of crystals. A very important development in the Evolet Anti-Scale catalyst is that the nanostructure on the surface of the catalyst decreases the enthalpy needed enough to allow all ions to form into crystals, even in cold water. Altogether, Evolet Anti-Scale media can be described as an artificial template that allows for all calcium and magnesium ions to form into harmless crystals. When the crystals growing, they lose their grip on the templates and are rinsed away with the water flow. Now new crystals can form on the template.nnLifetimenThe NSF Certified Evolet Anti-Scale media works chemical, salt and maintenance free and has a lifetime of 2-3 years. The Evolet Anti-Scale media does not have to be backwashed.nnEvolet Anti-Scale MedianChemical formula and composition: Glass Coated PolymernMineralogical composition: Ceramic TemplatennPhysical Propertiesn

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Bulk weight 750 kg/m3
Specific surface 270 m2/g
Colour light yellow balls
Mesh size 0.5-0.8 mm
Tolerance mesh size ≤ 0,3 mm 3,0%
Tolerance mesh size ≥ 1,2 mm 3,0%
Volume change in water Max. 60%
Moister Content 24-28%

nOperation Condition and Exchange Capacityn

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Free board up flow 60-70%
Service flow rate 30-50 m/h
Design concept at 150 ppm 2.0-3.5 liters per 1000 l/h flow
Design concept at 300 ppm 3.5-6.0 liters per 1000 l/h flow
Operating temperature 5°-70° C
pH Range 6-9
Media Lifetime 2-3 years
Chemical free, no backwash, no valve, no electricity

n

APPLICATION

n01. Scale prevention:nEvolet Anti-Scale media is applicable in a wide range of water treatment processes, from large-scale municipal systems to small-scale residential treatment units. Regardless of the system size, there are operational design parameters that must be considered to ensure effective, trouble free performance of the Evolet Anti-Scale media. Groundwater or surface water is simply pumped in up flow mode through a single or multiple Enpress pressure vessels with special up flow distribution head, containing the Evolet Anti-Scale media. We recommend you to use a gravel support layer for better water distribution. To improve efficiency it is proved to install 5-20 micron polypropylene cartridge system downstream after the system.The multiple pressure vessel design is either assembled in Parallel Flow or Series flow. Flow to each vessel is measured and totalized to record the volume of water treated. Do not exceed the recommended flow velocity to avoid problems in operation. Each system is being designed with flow regulating valve downstream to keep the system under the pressure. For non-stop operation it is being used as a duplex system where each system is going to be activated one after the other in 20-30 minutes cycle.n

02.

n

Food Service

nCoffee, Tee, Cola and Juice drinks, Espresso Machines, Steamers, Dishwashingn

03.

n

Commercial / Industrial

nCar washes, Laundries, Evaporative coolers, Hotels, Hospitals, Apartmentsn

04.

n

Residential

nLaundry, Dishwashers, Water heaters and boilers, Drinking waternnnnRead Moren

 

Shipping policy

At our Company, we understand the importance of timely delivery. We offer a variety of shipping options to suit your needs, including standard, expedited, and express shipping. Our dedicated team works diligently to process and dispatch your orders promptly, aiming to deliver them to your doorstep within the estimated timeframe.

We strive to provide fast and reliable shipping to our customers. Here\\\’s everything you need to know about our shipping process:

  • Dispatch: Within 24 Hours
  • Free shipping across all products on a minimum purchase of $99.
  • International delivery time 5 to 7 business days
  • Cash on delivery might be available
  • Easy 30 days returns and exchanges

Please note that delivery times are estimates and may vary depending on factors such as product availability, destination, and carrier delay

Returns policy

We want you to be completely satisfied with your purchase from our website. If for any reason you are not entirely happy with your order, we\\\’re here to help. Certain exclusions and conditions may apply, so we encourage you to review our detailed return policy for more information. Rest assured, our goal is to ensure your complete satisfaction with every purchase you make from our website

  1. Returned items must be unused, undamaged, and in the same condition as received.
  2. Original tags, labels, and packaging must be intact and included with the returned item.
  3. Proof of purchase, such as your order confirmation or receipt, is required for all returns.