Shimge Multistage Pump BL2-13
- Estimated Delivery : Up to 4 business days
- Free Shipping & Returns : On all orders over $200
Shimge Multistage Pump BL2-13
n
Application Limits of Vertical Pump
n
- n
- Medium temperature: normal type: 0℃~68℃ hot water type: 0℃~120℃
- Ambient temperature: +40℃
- Max ambient pressure: 1.0MPa
- Advisable to use a motor of a higher power in case that the density or viscosity of the medium is above that of water.
- pH: 5 to 8
n
n
n
n
n
n
n
n
| Water supply | BL | BL T |
| Filtration and transfer at waterworks | ● | ● |
| Distribution from waterworks | ● | ● |
| Pressure boosting in mains | ● | ● |
| Pressure boosting in high-rise buildings, hotels, etc. | ● | ● |
| Pressure boosting for industrial water supply | ● | ● |
| Industry | ||
| Pressure boosting | ● | ● |
| Process water systems | ● | ● |
| Washing and cleaning systems | ● | ● |
| Vehicle washing tunnels | ● | ● |
| Fire fighting systems | ● | ● |
| Liquid transfer | ||
| Cooling and air-conditioning systems(refrigerants) | ● | ● |
| Boiler feed and condensate systems | ● | ● |
| Machine tools(cooling lubricants) | ● | ● |
| Aquafarming | ● | ● |
| Transfer | ● | ● |
| Oil and alcohol | ● | ● |
| Glycol and coolants | ● | ● |
| Water treatment | ||
| Ultra-filtration systems | ● | ○ |
| Reverse osmosis systems | ● | ○ |
| Softening, ionizing, demineralizing systems | ● | ○ |
| Distillation systems | ● | ○ |
| Separators | ● | ○ |
| Swimming baths | ● | ● |
| irrigation | ||
| Field irrigation(flooding) | ● | ● |
| Sprinkler irrigation | ● | ● |
| Drip-feed irrigation | ● | ● |
n
n
n
n
n
n
- n
- Full-enclosed and ventilating two-pole standard motor
- Protection class: IP55
- Insulation class: F
- Standard voltage Single phase 220V-50Hz Three-phase: 380/400V-50Hz
- Standard motor efficiency: 11kW to 45kW: IE3, other: IE2, specific efficiency value for below table
n
n
n
n
n
n
n
n
n
n
nIf the pressure in the pump is lower than the vapor pressure of the medium, cavitation will occur, which will affect the performance of the pump. To avoid the cavitation and ensure the pump inlet has a minimum pressure, the maximum suction head should be calculated as below:n
nPb: Atmospheric pressure, bar (In close pipeline system, it can be considered as the system pressure);nNPSH: Net positive suction head, m (Value at a maximum flow of Q-NPSH curve);nHf: Suction pipeline loss (Value at a maximum flow of the corresponding pipeline);nHv: Medium vapor pressure, m (Medium vapor pressure at corresponding temperature, the default medium is water, as shown in figure4 on the right);nHs: Safety margin, m, general value is 0.5.nCalculation result: if H is positive, the pump is installed in a suction way, otherwise, it is installed in the downdraft way.nnNote: It is not necessary to do the above calculation under general conditions. Only when we use the pump in the following situations do we need to calculate the H:n1. Medium temperature is high;n2. The velocity of flow is larger than the rated value;n3. Suction head is big or the inlet pipeline is long;n4. System pressure is small;n5. Inlet condition is bad.nn
n
n
nSelection of pumps should be based on:n1. Duty point of the pumpn2. Dimensional data such as pressure loss as a result of height differences, friction loss in the pipeworkn3. Pump efficiencyn4. Pump materialsn5. Pump connectionsn6. Commonly used mechanical seal configuration tablesnn1. Duty point of the PumpnFrom a duty point, it is possible to select a pump on the basis of the curve charts shown in “performance curves/technical” data.nn2. Dimensional DatanWhen sizing a pump the following must be taken into account:n· Required flow and pressure at the draw-off point.n· Pressure loss as a result of height differences.n· Friction loss in the pipework (Hf) (Refer to Fig.1) it may.n· Highest efficiency at the estimated duty point.n· NPSH value.n· For calculation of the NPSH value, see the corresponding curves chart.nn3. Pump EfficiencynBefore determining the best efficiency point, the operation pattern of the pump needs to be identified. If the pump expected to operate as the same duty point, then select a BL pump which is operating at a duty point corresponding with the best efficiency of the pump.nAs the pump is sized on the basis of the highest possible flow, it is important always to have the duty point to the right on the efficiency curve (eta) in order to keep efficiency high when the flow drops.nn
n
n4. Pump MaterialnThe material variant should be selected based on the liquid to be pumped. BL wetted parts are made of AISI304. BLT pump body is made of cast-iron.nn5. Pump ConnectionsnnThe selection of pump connection depends on the rated pressure and pipework. The vertical centrifugal pump offers a wide range of flexible connections such as:n· Pipe threadn· Oval flangen· DIN flangen· Other connections on requestn· Commonly used mechanical seal configuration tablesnn6. Commonly used mechanical seal configuration tablesn
| Configuration | Configuration illustrate | Application Field | Configuration case |
| EUBV | Container-type E, hard alloy moving ring U, static ring leaching resin graphite B, fluorine rubber V | 1. Working condition regular under cold water 0 ℃ to 68 ℃, no particles, oil.n2. Working condition regular under hot water 68 ℃ to 90 ℃, no particles, with oil. | Normal |
| EQQE | Container type E, moving ring and static ring silicon carbide Q, EPDM E | Working condition: hot water 90 ℃ to 120 ℃, containing a small number of particles, no oil. | Normal |
| EQQV | Container type E, moving ring and static ring silicon carbide Q, fluorine rubber V | 1. PH = 5-7 acidic medium.n2. PH = 7-9, alkaline medium.n3. Working conditions: hot water 68 ℃ to 90 ℃, containing a small number of particles, oil.n4. With oil. | Customer-made |
| EUUE | Container type E, moving ring and static ring U, hard alloy U, EPDM E | 1. Under ice water 0 ℃.n2. A crystallization of alkaline medium.n3. Containing a large number of granular media.n4. More than 2 MPa pressure conditions.n5. No oil. | Customer-made |
n
n
n
n
| Model | Curve No. |
| BL(T)2,4 | 2 |
| BL(T)8,12,16,20 | 3 |
| BL(T)32-2-2~BL(T)32-7 | 1 |
| BL(T)32-8-2~BL(T)32-12 | 4 |
| BL(T)32-13~BL(T)32-15-2 | 5 |
| BL(T)45-2-2~BL(T)45-6 | 1 |
| BL(T)45-7-2~BL(T)45-9 | 4 |
| BL(T)45-10-2~BL(T)45-13-2 | 5 |
| BL(T)64-2-2~BL(T)64-5-2 | 1 |
| BL(T)64-5-1~BL(T)64-8 | 4 |
| BL(T)90-2-2~BL(T)90-4-2 | 1 |
| BL(T)90-4~BL(T)90-6 | 4 |
n
n
n
nThe limits of pressure and temperature are shown in the following fig. 4, the pressure and temperature are shown in the fig. 4.n
nWhen the pump is operating in the place where the ambient temperature is higher than 40℃ or altitude is higher than 1000m, the output power of motor P2 will decrease because of poor cooling caused by low air density. Therefore, in that case, the vertical pump should be equipped with a high-power motor.nn
n
n n
n
n
n
Shipping policy
At our Company, we understand the importance of timely delivery. We offer a variety of shipping options to suit your needs, including standard, expedited, and express shipping. Our dedicated team works diligently to process and dispatch your orders promptly, aiming to deliver them to your doorstep within the estimated timeframe.
We strive to provide fast and reliable shipping to our customers. Here\\\’s everything you need to know about our shipping process:
- Dispatch: Within 24 Hours
- Free shipping across all products on a minimum purchase of $99.
- International delivery time 5 to 7 business days
- Cash on delivery might be available
- Easy 30 days returns and exchanges
Please note that delivery times are estimates and may vary depending on factors such as product availability, destination, and carrier delay
Returns policy
We want you to be completely satisfied with your purchase from our website. If for any reason you are not entirely happy with your order, we\\\’re here to help. Certain exclusions and conditions may apply, so we encourage you to review our detailed return policy for more information. Rest assured, our goal is to ensure your complete satisfaction with every purchase you make from our website
- Returned items must be unused, undamaged, and in the same condition as received.
- Original tags, labels, and packaging must be intact and included with the returned item.
- Proof of purchase, such as your order confirmation or receipt, is required for all returns.







