Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.

20 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

VONTRON MEMBRANEn

Who is Vontron? What can RO membrane do?

nhttps://youtu.be/PzS7Y6fgFUsn

Installing A 4040 Vontron Membrane

nhttps://youtu.be/_ORPqr1olRwn

Dimensions Of A 4040 Membrane

nn

4″ LP Series Of Low Pressure RO Element

nThe LP (low pressure) series of aromatic polyamide compound membrane elements developed by Vontron Technology Co., Ltd. has the properties of low-pressure operation, high permeate flow, and excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc. Being suitable for desalting such water sources as surface water, underground water, tap water, and municipal water, etc., the LP series is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline wastewater and production of beverage-purpose water.nnLP series of the low-pressure elements is normally suitable for the treatment of brackish water, surface water, underground water, and municipality water with TDS that is less than 10000ppm. It is mainly used for producing various scales of bottle water, drinking water, industrial used pure water, high purity water, boiler replenishment water, also for wastewater reuse, material concentration, purification, and refining purposes.n

    n

  • Testing Conditions
  • n

n

    n

  • Testing Pressure: 225 psi (1.55Mpa)
  • n

  • The temperature of Testing Solution: 25 °C
  • n

  • The concentration of Testing Solution (NaCl): 2000ppm
  • n

  • pH Value of Testing Solution: 7.5
  • n

  • Recovery Rate of Single Membrane Element: 15%
  • n

n

    n

  • Operation Limits & Conditions
  • n

n

    n

  • Max. Working Pressure: 600psi (4.14Mpa)
  • n

  • Max. Feedwater Flow: 75gpm (17 m3/h) (for 8040) | 16gpm (3.6 m3/h) (for 4040)
  • n

  • Max. Feedwater Temperature: 45 °C
  • n

  • Max. Feedwater SDI: 5
  • n

  • Residual chlorine Concentration of Feedwater: <0.1ppm
  • n

  • pH Range of Feedwater during Continuous Operation: 3~10
  • n

  • pH Range of Feedwater during Chemical Cleaning: 2~12
  • n

  • Max. Pressure Drop of Single Membrane Element: 15psi (0.1Mpa)
  • n

n

Major Properties Of 4″ LP Element

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Model Active Membrane Area ft2(m2) Spacer Thickness mil Permeate Flow GPD(m3/d) Stable Rejection Rate % Minimun Rejection Rate &
LP100 100 (9.3) 28 2500 (9.4) 99.7 99.5
LP11-4040 90 (8.4) 28 3000 (11.4) 99.3 99.0
LP21-4040 100 (8.4) 28 2400 (9.1) 99.5 99.3

nNote: The permeate flow listed in the table is the average value. The permeate flow of single element is tolerance to ±15% of this value.n

4″ ULP Series Of Ultra Low Pressure RO Element

nThe ULP (ultra-low pressure) series of aromatic polyamide compound membrane elements developed by Vontron Technology Co., Ltd for the treatment of surface water and underground water. Its operation is about 2/3 of the low-pressure membrane, and the rejection rate can reach 99%. Thus it can reduce the investment cost of related pumps, pipelines, containers, and other equipment and operation costs of reverse osmosis system, and improve economic benefits.nnULP RO element is normally suitable for the treatment of brackish water, surface water, underground water, and municipality water with TDS that is less than 2000ppm. It is mainly used for producing various scales of bottle water, drinking water, boiler replenishment water, food processing, and pharmaceutical manufacturing industries, and other fields.n

    n

  • Testing Conditions
  • n

n

    n

  • Testing Pressure: 150 psi (1.03Mpa)
  • n

  • The temperature of Testing Solution: 25 °C
  • n

  • The concentration of Testing Solution (NaCl): 1500ppm
  • n

  • pH Value of Testing Solution: 7.0±0.5
  • n

  • Recovery Rate of Single Membrane Element: 15%
  • n

n

    n

  • Operation Limits & Conditions
  • n

n

    n

  • Max. Working Pressure: 600psi (4.14Mpa)
  • n

  • Max. Feedwater Flow: 75gpm (17 m3/h) (for 8040) | 16gpm (3.6 m3/h) (for 4040)
  • n

  • Max. Feedwater Temperature: 45 °C
  • n

  • Max. Feedwater SDI: 5
  • n

  • Residual chlorine Concentration of Feedwater: <0.1ppm
  • n

  • pH Range of Feedwater during Continuous Operation: 3~10
  • n

  • pH Range of Feedwater during Chemical Cleaning: 2~12
  • n

  • Max. Pressure Drop of Single Membrane Element: 15psi (0.1Mpa)
  • n

n

Major Properties Of 4″ LP Element

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Model Active Membrane Area ft2(m2) Spacer Thickness mil Permeate Flow GPD(m3/d) Stable Rejection Rate % Minimun Rejection Rate &
LP100 100 (9.3) 28 2800 (10.6) 99.5 99.2
ULP11-4040 90 (8.4) 28 2400 (9.1) 99.0 98.5
ULP21-4040 90 (8.4) 28 1900 (7.2) 99.4 99.0

nNote: The permeate flow listed in the table is the average value. The permeate flow of single element is tolerance to ±20% of this value.n

Important Information

n

    n

  1.  Any specific application must be limited within the Operating Limits and Conditions. We strongly recommend you to refer to the latest edition of the technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron Technology Co., Ltd. will assume no liability for all results.n2. The permeate flow listed in the table is the average value. The permeate flow of a single membrane element is within a tolerance not exceeding ±20% of the nominal value.n3. All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanetriol required in winter) for storage purpose, then sealed with a plastic bag in a vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation, and system standby, we recommend you soak the membrane elements with the protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfiten(foodstuff-purpose).n4. Discard the RO-filtered water produced during the first one hour after system start-up.n5. During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful to membrane elements. In case of any violation in using this kind of chemical medicament, Vontron Technology Co., Ltd. assumes no liability for any outcome incurred therefrom.
  2. n

n

Points of Attention

n1. All data and information provided in this manual have been obtained from a long-term experiment by Vontron Technology Co., Ltd. We confirm that these data and information are accurate and effective. Vontron Technology CO., Ltd. assumes no liability for any aftermath caused by the user’s failure in abiding by the conditions specified in this manual in use or maintenance of membrane products. It is strongly recommended that the user shall strictly abide by the requirements for the design, use, and maintenance of products and keep relevant records.n2. Along with technical development and product renovation, the information contained herein will be subject to modification without prior notification. Please visit the website of Vontron Technology Co., Ltd. for any update of the product.

 

Shipping policy

At our Company, we understand the importance of timely delivery. We offer a variety of shipping options to suit your needs, including standard, expedited, and express shipping. Our dedicated team works diligently to process and dispatch your orders promptly, aiming to deliver them to your doorstep within the estimated timeframe.

We strive to provide fast and reliable shipping to our customers. Here\\\’s everything you need to know about our shipping process:

  • Dispatch: Within 24 Hours
  • Free shipping across all products on a minimum purchase of $99.
  • International delivery time 5 to 7 business days
  • Cash on delivery might be available
  • Easy 30 days returns and exchanges

Please note that delivery times are estimates and may vary depending on factors such as product availability, destination, and carrier delay

Returns policy

We want you to be completely satisfied with your purchase from our website. If for any reason you are not entirely happy with your order, we\\\’re here to help. Certain exclusions and conditions may apply, so we encourage you to review our detailed return policy for more information. Rest assured, our goal is to ensure your complete satisfaction with every purchase you make from our website

  1. Returned items must be unused, undamaged, and in the same condition as received.
  2. Original tags, labels, and packaging must be intact and included with the returned item.
  3. Proof of purchase, such as your order confirmation or receipt, is required for all returns.